Re: (PMOD) U.S. Robotics Sportster 56000 Fax V4.0.1

Brad Martin (bradleyd@iglou.com)
Sat, 28 Aug 1999 14:16:58 -0500 (Central Daylight Time)

Yes. And I made a mistake. The command I gave should have been s13=66

But yes, a v.90 flash couldn't hurt either.

Brad

On Sat, 28 Aug 1999, Doug Hardie wrote:

> Thanks, but wouldn't it be better for her to get it flashed to V.90?
>
>
> At 23:59 -0700 8/27/99, Brad Martin wrote:
> >Doug
> >The ATI commands show that this modem is an X2 modem not flashed to V.90.
> >That explains the 31,200 connect you're seeing. That also explains why
> >the suggestion you tried failed; it was shooting for v.90 or X2 speeds,
> >which you cannot obtain connecting to a PM with X2. Because the minimum
> >was too high, you did not connect at all.
> >
> >Try
> >s13=64
> >to disable fast retrains--worked wonderfully for a friend of mine.
> >
> >Brad
> >
> >
> >On Fri, 27 Aug 1999, Doug Hardie wrote:
> >
> >> I am looking for ideas to help this user's connections stay up. She
> >> disconnects within a couple of minutes. Mac running System 7.1. I've had
> >> her try the one suggestion I found in the archive (AT&F1&M5&N29&U28) and
> >> that prevented any connections.
> >>
> >>
> >> >>ATI0
> >> >>5601
> >> >>ATI1
> >> >>478F
> >> >>ATI3
> >> >>U.S. Robotics Sportster 56000 Fax V4.0.1
> >> >>ATI6
> >> >>U.S. Robotics Sportster 56000 Fax Link Diagnostics...
> >> >>
> >> >>Chars sent 663 Chars Received 2403
> >> >>Chars lost 0
> >> >>Octets sent 548 Octets Received 1243
> >> >>Blocks sent 33 Blocks Received 49
> >> >>Blocks resent 2
> >> >>
> >> >>Retrains Requested 0 Retrains Granted 0
> >> >>Line Reversals 0 Blers 1
> >> >>Link Timeouts 0 Link Naks 1
> >> >>
> >> >>Data Compression V42BIS 1024/32
> >> >>Equalization Long
> >> >>Fallback Disabled
> >> >>Protocol LAPM
> >> >>Speed 31200/28800
> >> >>Last Call 00:04:46
> >> >>
> >> >>Disconnect Reason is Escape code
> >> >>Equalization Long
> >> >>Fallback Disabled
> >> >>Protocol LAPM
> >> >>Speed 31200/28800
> >> >>Last Call 00:04:46
> >> >>
> >> >>Disconnect Reason is Escape code
> >> >>ATI7
> >> >>Configuration Profile...
> >> >>
> >> >>Product type US/Canada External
> >> >>Options V32bis,V.34+,x2
> >> >>Fax Options Class 1/Class 2.0
> >> >>Line Options Caller ID, Distinctive Ring
> >> >>Clock Freq 92.0Mhz
> >> >>Eprom 256k
> >> >>Ram 64k
> >> >>
> >> >>EPROM date 2/20/97
> >> >>DSP date 2/20/97
> >> >>
> >> >>EPROM rev 4.0.1
> >> >>DSP rev 10.2.1
> >> >>0
> >>
> >> -- Doug
> >>
> >>
> >> -
> >> To unsubscribe, email 'majordomo@livingston.com' with
> >> 'unsubscribe portmaster-modems' in the body of the message.
> >>
>
>
> -- Doug
>
>
> -
> To unsubscribe, email 'majordomo@livingston.com' with
> 'unsubscribe portmaster-modems' in the body of the message.
>

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-modems' in the body of the message.