We have a problem with the Motorola SM56K modem, We Upgrade the divers of=
the
client to the lastest version 3.02.70 (build 70) from
www.motorola.com/networking/products/softmodem.html and put the %B18 to l=
imit
the speed to 33.6.
The modem can conect and we can logon (the radius show that it was logon =
and
asigned an ip address), but after that the client's computer hangup and
disconect, we look at the log of the connection and find this:
>07-07-1999 20:30:26.36 - Recv: <cr><lf>CONNECT 31200/LAPM/V42BIS<cr><lf>=
=20
>07-07-1999 20:30:26.36 - Interpreted response: Connect=20
>07-07-1999 20:30:26.36 - Connection established at 31200bps.=20
>07-07-1999 20:30:26.36 - Error-control on.=20
>07-07-1999 20:30:26.36 - Data compression on.=20
(to this is all ok)
>07-07-1999 20:30:42.24 - Hanging up the modem.=20
>07-07-1999 20:30:42.24 - Hardware hangup by lowering DTR.=20
>07-07-1999 20:30:43.44 - WARNING: The modem did not respond to lowering =
DTR.=20
>Trying software hangup...=20
>07-07-1999 20:30:43.44 - Send: +++=20
>07-07-1999 20:30:43.46 - Recv: <cr><lf>OK<cr><lf>=20
>07-07-1999 20:30:43.46 - Interpreted response: Ok=20
(Starting the hangup)
>07-07-1999 20:30:43.46 - Send: ATH<cr>=20
>07-07-1999 20:30:45.49 - Recv: <no response>=20
>07-07-1999 20:30:45.49 - WARNING: Unrecognized response. Retrying...=20
>07-07-1999 20:30:45.49 - Send: ATH<cr>=20
>07-07-1999 20:30:45.63 - Recv: <cr><lf>OK<cr><lf>=20
>07-07-1999 20:30:45.63 - Interpreted response: Ok=20
>07-07-1999 20:30:45.63 - 115200,N,8,1=20
>07-07-1999 20:30:46.63 - Session Statistics:=20
>07-07-1999 20:30:46.63 - Reads : 618 bytes=20
>07-07-1999 20:30:46.63 - Writes: 500 bytes=20
>07-07-1999 20:30:46.63 - Motorola SM56 PCI Speakerphone Modem closed. =20
Why is the modem dissconecting ?? we try the &D1 and &D comands to ignore=
the
DTR and it do the same, How can we configure the modem to mantain the con=
ection
?? can it be problem of software ?? or hardware ?? please help us !! :-)
Tanks in advance
--=20
Mensaje sin acentos=0D
=0D
Ing. Alexandro Conde Martinez ---------> Alcon=0D
WAN & Dial up Manager
mailto:alcon@ciateq.mx <http://ciateq.mx/~alcon> =0D
ICQ# 6269259 Tel:+52 (4) 211-26-00 Ext. 525
-
To unsubscribe, email 'majordomo@livingston.com' with