Re: (PMOD) Disable v42/v42bis

Mike Tancsa (mike@sentex.net)
Sun, 19 Dec 1999 09:01:38 -0500

At 08:11 AM 12/19/99 , Vladimir Litovka wrote:
>On Sun, 19 Dec 1999, Mike Tancsa wrote:
>
>> > It is pity... Result of 'show modem' says, that many of disconnections are
>> > 'LAPM DISCONNECT'. I think, that disabling LAPM error correction and using
>> > MNP instead of LAPM will help...
>>
>> LAPM DISCONNECT is a negotiated disconnection by the client and is normal.
>> e.g. NT with a Supra MAX always shows LAPM Disconnect when I tell RAS to
>> hang up.
>
> On the other hand there are also 'NORMAL' disconnects - how I should treat
> them?

Run a version of RADIUS that supports VSAs, and look at the termination
reason in your RADIUS logs. Other 'normal' reasons include
PPP-TERM-REQUEST. I dont think this will show up under show modem.

---Mike
**********************************************************************
Mike Tancsa * mike@sentex.net
Sentex Communications Corp, * http://www.sentex.net/mike
Cambridge, Ontario * 519 651 3400
Canada *
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-modems' in the body of the message.