Once upon a time Rob Poland shaped the electrons to say...
>1.How does a RADIUS entry look like for a PPP-user that is only
>allowed to login on ports 4,5 and 6? Something like this doesn't work:
You can't do this. RADIUS, as we provide it, does not support limiting
users to a range of ports.
>2. I'm using a dialback entry in the Radius users file. This entry
>works but how can I let the modem dial pulse instead of tone. I put
>the modem on pulse dailing and when I dial on that port it dials
>pulse. But when the dialback entry dials back it is uses tone dailing.
> This tone dialing must come explicitly from the dialer, how can I
>change this? Or how can I change me Radius entry for pulse dialing.
I've been here a year and you're the first person to ask this, had to go
check... Can't be done. 'ATDT' is hardcoded right into the ComOS.
But can't you do ^HP in your init string. I do it all the time with a
windows app I have that has ATDT hard coded. The ^H is a backspace and P is
pulse.
Mark Wilson
Net Direct