The setting options are as follows:
Black Box Line Drivers:
It has 5 applicable dip switches
OPTIONS CURRENT SETTING
1. DCE/DTE DCE
2. RTS/CTS ON/OFF ON
3. Echo on/off OFF
4. Carrier control On/off (controlled by RTS) OFF
5. Impedance Hi/Lo Lo
I currently have the same settings for both drivers.
PORTMASTER Settings
Mode: extended
Port Type: Dialnet
Dialnet Type: Hardwired
Protocol: PPP/IP
MTU: 1500
Baud: 19200
Modem Control: OFF
Flow Control: RTS/CTS
IP Destination: 163.118.5.251
Netmask: 163.118.5.0
Routing: Listen
Compression: Disabled
PC Settings (Trumpet Winsock Settings)
IP: 163.118.5.251
MTU: 1500
TCP RWIN: 2048
TCPMSS: 516
TCP RTO MAX: 60
Demand Load TO: 5secs
Hardware Handshaking: On
Compression: Off
3 options for Online Status Detection:
ppp trace results
1. none conf req times out
2. DCD (RLSD check) nothing happens
3. DSR check conf req. times out
Windows control panel settings:
Baud: 19200
Flow control: Hardware
msd reports:
Baud: 19200
DSR and CTS on
Any Help would be greatly appreciated, since I have many locations which
would benefit from this type of connection, and my experience with the
portmaster and line drivers is limited.
###############################################################################
Tony Carroll
Network Administrator Tel: 407/768-8000 x8107
Academic and Research Computing Services FAX: 407/722-2863
Florida Tech.
150 W. University Blvd. email: tony@fit.edu
Melbourne Fl. 32901