Re: 5-BRI fails intermittently

Jay Hennigan (jay@west.net)
Tue, 4 Jun 1996 09:42:53 -0700 (PDT)

On Tue, 4 Jun 1996, Jon Gefaell wrote:

> Regarding these symptoms. I've just setup a 2er W/ 10 Async and 5 BRI.
>
>
> 1.) PMPConsole for Windows (*ugh*) is ultra bug ridden. Among other
> lossage it won't allow a SPID with a leading 0.

Haven't tried this, I use the command line. Seems to me that the Windows
software was pre-ISDN.

> 2.) after setting up the BRI ports by hand, the lights on the back of
> the unit were solid, but the ports would show 'NO SESSION' or whatever.

Probably "NO SERVICE".

> Telco said they could connect right up to my equipment. (Past the NT1)
>
> I had to power cycle and they came right back up.

Covered in the docs. You need to reboot for changes to ISDN switch type
to take effect.

> This was just 3 BRI's, leaving S16-19 unconfigured. The next day the
> telco hooked up the other two lines. Set them up by hand, they reset
> just fine W/O a need for a reboot or power cycle.

Probably because the switch type had been correctly specified by then.

----