Re: Best initialization string for USR Sportster 33.6?

MIX System Operator (sysop@mixcom.com)
Thu, 27 Jun 1996 13:39:58 -0500

At 06:48 PM 6/26/96 -0400, you wrote:
>What is the best init string for USR Sportster 33.6 modems for use with
>PM2e servers?
>
>I am currently using at&f1s0=1&w

AT&F1M0Q2&M5S0=1S2=255S13=1&W&W1
Q2=show results when originating
&M5=lock ARQ
S2=escpae char > 128 disables
S13=reset on DTR drop

One thing to note is I found that using the modem table to just initalize
the modems *seems* to work better. A 'set al mo usr' and then 'res all'
with a check on each port to see if it configured properly. After that I
'set al mo' to clear the entries.

>I have seen some postings on Usenet about adding s10=7, is this valid? I
>guess the default s10 register is set to 14.

Backwards, the default is 7 for .7 seconds. Now that the ability to track
each port for Session Termination reasons is in place, on a statisical basis
I can find out increasing S10 to about 30 will help any. Otherwise my
thought are if CD is lost for .7 seconds, the line is bad and another call
may give a better virtual circuit (in the case of some local CSO's, not very
likely).

Plan to try it and see what happens for next week after the log rolls on
Friday night/Saturday morning.

------------
Jeff Mountin
sysop@mixcom.com

MIX Communications
Serving the Internet since 1990

Sure my business card says "Senior Network Administrator"