Re: Best initialization string for USR Sportster 33.6?
MIX System Operator (sysop@mixcom.com)
Thu, 27 Jun 1996 13:44:55 -0500
At 04:44 PM 6/26/96 -0700, Network Operations Center wrote:
>I use:
>AT&F1&C1&D2S0=1S13=1&W
>on all of my USR modems. With this init string I have never had to power
>cycle my modems and don't get cannot connect problems. Some say that the
>S13=1 is the default and unnecessary, but before I added it I was having
>all kinds of problems. Of course YMMV.
Both &C1 and &D2 are defaults. The default for S13 is 0. These apply to
both the new 33.6's and older 28.8's.
------------
Jeff Mountin
sysop@mixcom.com
MIX Communications
Serving the Internet since 1990
Sure my business card says "Senior Network Administrator"
They still make me do just about anything.