Line Ordering Code

Simon Nuthall ((no email))
Fri, 28 Jun 1996 08:01:54 -0700 (PDT)

Pass this on to the telco to assist in the provisioning of your lines.Hopefully
this helps you all with the ordering of your ISDN lines, please feel free to
pass this on.

>Subject: Line Ordering Code
>
>
>
>Table A3: National ISDN-1 (NI-1) Switch Translations
>
>---------------------------------------------------------------
>Attribute Parameter
>---------------------------------------------------------------
>Line 2B+D
>
>Line Code 2B1Q
>
>Terminal Type A
>
>MAX B Channels 2
>
>B1 CSD (or CSVD)
>
>B2 CSD (or CSVD)
>
>D signalling
>
>CSD 2
>
>CSD CHANNEL any
>
>CSD LIMIT 2
>
>ACT USR Yes
>
>Dynamic TEI Yes
>
>EKTS No
>
>MTERM 1
>
>CA PREF 1
>
>Call Appearances Idle
>
>Protocol Version Control 2
>
>Release Key No
>
>Ringing Indicator No
>---------------------------------------------------------------
>
>Table A4: 5ESS Custom Multi-Point Switch Translations
>
>---------------------------------------------------------------
>Attribute Parameter
>---------------------------------------------------------------
>Line 2B+D
>
>Line Code 2B1Q
>
>Terminal Type A
>
>MAX B Channels 2
>
>B1 CSD (or CSVD)
>
>B2 CSD (or CSVD)
>
>D signalling
>
>CSD 2
>
>CSD CHANNEL any
>
>CSD LIMIT 2
>
>ACT USR Yes
>
>Dynamic TEI Yes
>
>EKTS No
>
>MTERM 1
>
>CA PREF 1
>
>Autohold No
>
>OneTouch No
>
>Display No
>
>Call Appearances Idle
>---------------------------------------------------------------
>
>Table A5: 5ESS Custom Point-to-Point Switch Translation
>
>---------------------------------------------------------------
>Attribute Parameter
>---------------------------------------------------------------
>Terminal Type A
>
>Call Appearances 1
>
>Display No
>
>Channels for CSV per DN 1
>
>Channels for CSD per DN 1
>---------------------------------------------------------------
>
>Table A6: DMS-100 Custom Switch Translations
>
>---------------------------------------------------------------
>Attribute Parameter
>---------------------------------------------------------------
>Line 2B+D
>
>Line Code 2B1Q
>
>Terminal Type A
>
>MAX B Channels 2
>
>Circuit Switched Service Yes
>
>CSD/CSV CHANNEL Any
>
>Signalling Functional
>
>Dynamic TEI Yes
>
>EKTS No
>
>Protocol Version Control 1
>
>Max # Programmable Keys 3
>
>Release Key No
>
>Ringing Indicator No
>---------------------------------------------------------------
>
>
>
>

-- 
Simon