FR RS232 port not functioning in 3.3.2?

Igor V. Semenyuk (iga@sovam.com)
Fri, 13 Sep 1996 02:17:32 +0400 (MSD)

Hello!

Before I go down on Livingston with this can anyone confirm the problem?

PROBLEM:

ComOS 3.3.2c1, PM2ER-30, W1 port Frame Relay 64K RS232 connection,
clocks from the mux - DOESN'T work.
ABSOLUTELY the same configuration, but ComOS 3.3.1 - DO work as a charm.

The tests were very simple: FR setup, load ComOS 3.3.1, W1 get into
ESTABLISHED state in a few seconds. Upgrade to 3.3.2c1 via pmconsole,
reboot (without powering off, but that doesn't matter), W1 always
stays in IDLE state. "Speed" in "show w1" output contains "Ext UNKNOWN".
Downgrade to 3.3.1, reboot - it's ok again.

Tested on 2 boxes. 3.3.2 is supposed to be affected as well.

This is related to the problem I posted a message about 3 weeks ago.
The remote PM2ER stopped talking over FR link apparently because it
had RS232 connection.

TIA.

-- 
Igor V. Semenyuk                    Internet: iga@sovam.com
SOVAM Teleport                      Phone:    +7 095 258 4170
Moscow, Russia                      Fax:      +7 095 258 4133