Thanks
--Per Hedeland
per@erix.ericsson.se
ComOS - Livingston PortMaster
login: !root
Password:
Command> version
Livingston Enterprises PortMaster Version 3.3.1
System uptime is 1 days 23 hours 17 minutes
Command> show table modem
Short Name Long Name Type
---------------- -------------------------------------------------- ------
powerbit PowerBit 34-ed 7075 User
Command> set s0 modem powerbit
Modem type for port S0 changed from to powerbit
Command> save s0
Saving port S0
New configurations successfully saved.
Command> reset s0
Resetting port S0
Command> show s0
----------------------- Current Status - Port S0 ---------------------------
Status: INITIALIZING
...
Modem Control: on on
Modem Config: Initializing powerbit
Hosts: super default
...
Command> show s0
----------------------- Current Status - Port S0 ---------------------------
Status: IDLE
...
Modem Control: on on
Modem Config: Configured powerbit
Hosts: super default
...
Command> reboot
Rebooting PortMaster....
Command> Connection closed by foreign host.
...
ComOS - Livingston PortMaster
login: !root
Password:
Command> show s0
----------------------- Current Status - Port S0 ---------------------------
Status: IDLE
...
Modem Control: on on
Hosts: super default
...
Command> version
Livingston Enterprises PortMaster Version 3.3.1
System uptime is 0 minutes
Command> set s0 modem powerbit
Modem type for port S0 changed from to powerbit