line hunting

Alexander Zatko (ptd@oz.net)
Tue, 03 Dec 1996 11:35:23 -0800

I recently had my local phone company to put mu ISDN numbers into a hunt
group. It seems the hunting is working in a sense that the call is being
routed from s10 to s11, but the connection can not be established. I
have on my premises PM2-ER with ISDN card. On the other end I have 2
clients with Pipeline 130 and 75 respectively. When one of my clients
has established connection to s10 (published number) and the other
client tries to establish the connection, the call is rejected.

Here is the log:

S11: Sending Request Connect - 64Kbps / Data
S11: Received Disconnect Ack Call Rejected
S11: Received Call Clear

Can anybody help me with an advice?

Alexander