On Sun, 8 Dec 1996 14:01:06 -0500 you wrote:

>We just put in an order for a PM3 2PRI and I have this question.
>
>The Telco tells us that the second PRI will have 24 channels and use the
>signaling from the first PRI.
>
>Does the PM3 support this and is this the normal scenario????
>

No it does not. The telco was referring to NFAS. You have to ask for 23B +
1D on each PRI.
--Marty

****************************************************************