Once upon a time Alex Rubenstein shaped the electrons to say...
>1) The local telco said that because we will have three PRI's with only one
>phone number (that is correct, one big hunt group), we need to order one
>PRI with 23B = 1D, and the other two 24B. How will having multiple PM3's
>come into play with this?

Tell them you CANNOT support that. ALL of the PRIs must me 23B+D. Most
switches support hunt groups across mutliple PRIs without NFAS (D channel
sharing). Another issue - NFAS is generally only within a chassis. So
the best you would do is one 23B+D and one 24B in a PM-3.

>2) Any plans for Multi-Chassis ML PPP ?

Already in there.

-MZ

--