> On 31-Dec-96 MegaZone wrote:
>
> >I suggest resetting the entire box to factory defaults:
> >
> >'set register 0xffff 0x0102'
> >
> >And all settings will be factory.
>
> Do I have to be logged in from S0 as console? The reason I ask is
> that I did it from a telnet session and nothing appeared to change.
> It paused approximately 5 seconds then displayed
>
> "Successfully formatted FLASH2"
>
> but a "show global" displays all the old (non-factory) settings.
Reboot, and it will reload config from FLASH. DO NOT do a "save all"
first, because you will re-save the config back into the erased flash!
The PM, unlike some other evil products, does not exec out of flash
(well, I think the system messages are, but those are critical). This
allows you to do software updates remotely without interrupting service
(except for a reboot).
> _____ ___ ___ ___
> (_ _)( )( \/ ) Tim Moloney Think of something
> ) ( ) ( ) ( moloney@netsrq.com witty and imagine it
> (___) (___)(__)\/(__) Sarasota, Florida was written here.
>
>
Tom