Re: New Point to Point T-1 Locking up ????
John G. Thompson (jgt10@livingston.com)
Sun, 4 May 1997 11:40:25 -0700 (PDT)
On Sat, 3 May 1997, Al Hopper wrote:
>
> On Sat, 3 May 1997, Jay Hennigan wrote:
>
> > On Sat, 3 May 1997, Rick Wagner wrote:
> >
> > > When I set up the circuit everything runs fine for about 10 minutes and
> > > then traffic stops flowing. If I do a reset S1 at one end the circuit goes
> > > into a connecting state and will not come back up until I do a hard reboot
> > > of the TSU.
> >
> > How is the circuit clocked? You may need to set one of the TSUs to
> > internal clock and the other one to network clocked. In some cases the
> > clock is supplied by telco, and both need to be set to network.
> >
> > Consult with the telco and ascertain how the circuit is clocked and set
> > your TSUs accordingly.
>
> On a point 2 point circuit (usually) the telco does not supply clock. In
> almost every other case the telco will supply the (sync) clock. Mr Jay is
> indeed correct. Also the circuit pairs should be flipped somewhere in the
> middle. Since you're seeing data the crossover must be OK.
If the DSUs are Adtran TSU 1000s or the T1/FT1 check that the
config->port->TX clock is INT and not INT-INV. Inverting the TX clock to
the Livingston products will cause the connection either to not work at
all or perform very badly.
Learned that one the HARD way! :/