Re: OR/U's versus Pipeline 75 (fwd)

MegaZone (megazone@livingston.com)
Tue, 20 May 1997 17:13:50 -0700 (PDT)

Once upon a time Jacob Suter shaped the electrons to say...
>Will Stac compression work on low speed sync lines too (ie - 56K,
>frac-t1's, etc?)

Technically yes - just negotiate CCP during PPP.

Officially we are committing to it on OR-ISDN units and the PM-3 for ISDN.

We plan to evaluate it on OR-SYNC units and the PM-3 for leased lines.
We expect that at some point the clock speeds would be too high for
compression to be efficient. So *if* we do it, it will likely auto disable
itself when the line speed goes above a certain level.

Ie, it makes some sense on a 64K or 128K line - but NOT on a full T1.

-MZ

--
Livingston Enterprises - Chair, Department of Interstitial Affairs
Phone: 800-458-9966 510-737-2100 FAX: 510-737-2110 megazone@livingston.com
For support requests: support@livingston.com  <http://www.livingston.com/> 