Re: telekom S2M

Frank Heinzius (frimp@mms.de)
Wed, 21 May 1997 13:29:32 +0000

Hi,

On 21 May 97 at 12:40, Norbert Esch wrote:

> Hi,
>
> is there anybody who connect a portmaster 3 PM-3A*E to a telekom S2M
> connection?
>
> The PRI Status LED indicated that there is no physical synchronization with
> the switch (green off, red on). The S2M LED at the S2M Connector is off,
> and the telekom said that the connector is functional. The command show
> line0 reports
>
> ---------------------- line0 - E1 2.048 Mbps -----------------------
>
>

Wrong config. You have to set the lines to ISDN, not to E1. E1 is for leased lines like
2MS or 2MU. Just do "set line0 isdn" and reboot. Also set the global switch type to EURO
or NET5 (set isdn euro) before the reboot.

Frank

--
Frank M. Heinzius             MMS Communication GmbH
mailto:frimp@mms.de           Eiffestrasse 598
http://www.mms.de             20537 Hamburg, Germany
Phone: +49 40 211105-0        Fax: +49 40 210 32 210