Hello
I have a customer with 2 office routers. 1 in US and 1 in England
I have the dial on demand locations working fine.
If England calls US all is fine.
If US calls England all is fine for 1 min, then the England end sends a LCP disconnect request and the
Line drops. Then imediately the England end dials up the US end and all is then fine. Idle timeout set to 2
mins both ends. US has ComOS 3.4.2, England has ComOS 3.5. Is there a good reason for this problem. I
saw some bug fix in 3.5 regarding ISDN forcing idle in some situations. If this is what is happening I will get
them to upgrade.
Also, How safe is it to upgrade ComOS over the ISDN link. And if so, is it wise for me to set up a network user
on their OR so that I can dial in and do the work. I have had major issues about upgrading IRX over leased
line link. I don't want that to happen to the US one.
Thanks
James
My PGP Public key is at http://www.superbug.demon.co.uk/public.asc
PGP Public Key Fingerprint = 9C A0 3E 42 E2 C8 39 E1 37 0A 10 8F E6 69 86 89