This is just wrong. Please let me know who said this - not only is it
wrong, it is dangerous advice.
>The reason for all this is that I have two Max4004's and in radius I have
>this entry.
>
>joeuser Password = "UNIX"
> Framed-Protocol = PPP,
> Login-Service = Rlogin,
> Login-Host = 207.201.x.x,
> Ascend-Idle-Limit = 1800
>
>This allows the user to log on with either a term emulator for shell
>access or with a PPP dialer.
This is not valid for Livingston. An entry must be shell OR PPP. NOT
both. In fact, I don't think that is technically a valid RADIUS entry.
Ascend has done a lot of extensions.
And the Ascend-Idle-Limit is an Ascend attribute that doesn't work with
Livingston. I don't believe Ascend supports the standard RFC attrib
for the same thing (we do).
-MZ
-- Livingston Enterprises - Chair, Department of Interstitial Affairs Phone: 800-458-9966 510-737-2100 FAX: 510-737-2110 megazone@livingston.com For support requests: support@livingston.com <http://www.livingston.com/> Snail mail: 4464 Willow Road, Pleasanton, CA 94588