Re: (PM) static IP users

Brian Elfert (brian@citilink.com)
Thu, 18 Mar 1999 10:23:59 -0600 (CST)

On Thu, 18 Mar 1999, Richard Morrell wrote:

> This is fine for T1 delivered services, but what happens with the E1
> version of the pm3 (which is capable of serving 60 ports)? It would make
> a lot of sense for this to annnouce /26 subnets in this case.

Just set the pool size in the PM3 to 64. Sure, this'll waste 4 IP
addresses, but it will broadcast a single route if set on the right
boundary.

Brian

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>