Re: (PM) Busy on new PM3

Thomas C Kinnen (tkinnen@livingston.com)
Fri, 19 Mar 1999 07:55:15 -0800

Larry wrote:

> Were moving in to our new building and moving equipment
> we picked up a new PM3 the one with the new DSP's its running 3.8.2
> and configured the same as all the others we were planing to just swap
> units
> to keep our down time to a minimum but the new unit will not take a call
> it returns a busy signal. We know its not a Telco problem putting the old
> unit back
> problem goes away.
> lines are PRI esf b8zf

Are you sure the PM is configured the same? If the ports are configured for
dial out only and not dial in that can happen. what does a show global,
show all and show s0 report?

-- 
Thomas C Kinnen - <tkinnen@ra.lucent.com> <tkinnen@sobhrach.com>
[RADIUS Test Engineer] - LUCENT Technologies RABU
"All of the opinions stated above are my own and not my employer's,
unless they were given to me by my employer"
-