(PM) NO-SERVICE on E1 PRI

Mikel (mikel@sub.net.au)
Fri, 02 Apr 99 15:45:13 +1000

I have a PM3 connected to a E1 EuroISDN (Australian Telstra Onramp) line
running 3.8.2

show line0 gives me:

line0 - E1 Primary Rate ISDN
Status: UP F1 Framing: CRC4 Encoding: HDB3 PCM: a-law

Violations:
Bipolar 0
CRC4 0
E-Bit 107
FAS Bit 0

The E-Bit errors are not increasing though (I have logged a call with the
Telco none the less).

show s0 gives me:

Status: NO-SERVICE
Modem-Status: DCD- CTS+ TELCO+

show m0 gives me:

Card Type: LU1675 Chipset
State: Ready

Now, a search on the WWW pages tells me that DCD- CTS+ TELCO+ means the
line and switch type is fine but the SPID is not set. However, I didn't
know you have to set a SPID on EuroISDN lines and further down the page
indeed it says that SPID's only need to be set for US isdn.

Help?

Regards,

Mikel

-- 
-----------------------------------------------------------
Mikel Lindsaar        |  "The dream is the foundation,
mikel@sub.net.au      |        of our society!" 
-----------------------------------------------------------
SubNet!                         http://www.sub.net.au/
-----------------------------------------------------------

- To unsubscribe, email 'majordomo@livingston.com' with 'unsubscribe portmaster-users' in the body of the message. Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>