Strange problems with PM3-3.8.2 [RE: (PM) (ANNC) ComOS 3.9b8 avai

Peter A. Sang (pesa@sang.de)
Thu, 15 Apr 1999 11:19:44 +0200

Interesting - I'm having similar problems here (PM3/1 E1), but didn't
noticed it might be caused by 3.8.2.

Authentication works fine, but no network connection is established for SOME
users - majority works fine. There's no obvious pattern, but if the problem
starts with a user, this very userNAME will not get a connection again until
PM3 is rebooted.

Did you escalated it to technical support? Anyone else seeing this?

Mit freundlichem Gruss,

Peter A. Sang
SANG Computersysteme GmbH * Kruppstr. 82-100 * 45145 Essen * Germany
T: +49-201-82020-0 * F:-40 * http://sang.net * mailto:pesa@sang.net
* Microsoft Solution Provider - Internet/Intranet Specialist *

> -----Original Message-----
> From: jon-lists [mailto:jonlist@flanet.com]
> Sent: Monday, April 05, 1999 5:23 PM
> To: portmaster-users@livingston.com
> Subject: Re: (PM) (ANNC) ComOS 3.9b8 available for open beta for
> PortMaster 3
>
[...]
any problems? I'm not using 3.8.2 because of some strange
> problems I was
> having with it (wouldn't give callers network connections
> after X days of
> uptime, rebooting cured it until it would crop up again) and
> was forced to
> move back to 3.8 to resolve it.
>
[...]
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>