Re: (PM) Pipeline 75 dialing into PM3/CT1

Thomas C Kinnen (tkinnen@livingston.com)
Fri, 16 Apr 1999 08:47:06 -0700

Dan Machesky wrote:
>
> Trying to just make a single channel V.120 connection from a Pipeline 75 to
> a PM3 w/ct1's, with no success.

You are making a VOICE call correct?

> Link-Discriminator-for-BACP [0x17], length: (4 bytes), [0x000D]
> Link-Discriminator-for-BACP [0x17], length: (4 bytes), [0x4878]
> Link-Discriminator-for-BACP [0x17], length: (4 bytes), [0x4878]

Have you tried turning off BACP?

-- 
Thomas C Kinnen - <tkinnen@livingston.com> <tkinnen@sobhrach.com>
[RADIUS Test Engineer] - LUCENT Technologies RABU
"All of the opinions stated above are my own and not my employer's,
unless they were given to me by my employer"
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>