I had a similar situation a few months back, disconnects started
increasing dramatically then the unit started rebooting every day then
every few hours.
Lucent tech support had me do a tftp reload of ComOS and that didn't help
so they replaced the unit. Problem disappeared.
I love my PM3's but even the best equipment fails from time to time. Call
tech support and open a ticket.
John
-------------------------------------------------------------------------
NetRom Internet Services 973-208-1339 voice
john@netrom.com 973-208-0942 fax
http://www.netrom.com
-------------------------------------------------------------------------
On Fri, 7 May 1999, Paul Carpenter wrote:
> I'm running 5 PM3s. I loaded the new modem code into all of them and it
> seems to have made a slight improvement in the percentages of Lost
> Carrier disconnects and Call Circuit Closed Disconnects.
>
> One problem has stayed with me, though. Four of the Portmasters run
> around 7.5% Call Circuit Closed disconnects and around 1% Lost Carrier
> disconnects. One box runs around 23% CCC disconnects and 2.5% Lost
> Carrier disconnects. All the T1s show clean with no errors.
>
> All are located in space leased inside the telco building and are set up
> identically.
>
> Any thoughts?
>
>
>
> -
> To unsubscribe, email 'majordomo@livingston.com' with
> 'unsubscribe portmaster-modems' in the body of the message.
>
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-modems' in the body of the message.