Re: (PMOD) Receive Level: PM3 3.8.2c2 1675 LUCENT DSPs

Jay Hennigan (jay@west.net)
Sat, 22 May 1999 12:34:50 -0700 (PDT)

On Sat, 22 May 1999, Carlton Houston wrote:

>
> List-
>
> Is the receive level being +2dB to -7.5dB a big deal?
>
> Looks like the+ side is to spec, but the other side is not... Anyone have
> any ideas if I should be concerned or not?

It's a range. The level meter is not very precise, and is telling you
that the signal is somewhere between -7.5dBm and +2dBm. This is fine,
and what you want it to be. The other ranges are -7.5 to -15, -15 to -22.5
and below -22.5. There may also be one for signals hotter than +2 but I
haven't seen it.

If you want greater precision, a T-Berd will do this and a lot more.
Not cheap. Or an RMS voltmeter with good frequency response and a
precision terminator.

In the real world, don't sweat it as long as the error counts aren't
climbing.

-- 
--        Jay Hennigan     jay@west.net    805-884-6323          --  
WestNet:  Internet service to Santa Barbara, Ventura and the world.