:> Switch type, spid #'s, directory #'s. Did you check em?
:
:Those are for the user end, no? The user side config's are correct because
:they do log in eventually. Were there erasures in the PM3 configuration?
You have to set isdn info on your pm 3 as well. Switch type at the very
least. I think the default is National.
:75. I dial several times, but each time it shows me connect for an instant
:but never brings the channel up <on my router>. Then it disconnects. I
:dial again. Same thing. After about 7 tries I get one channel up, some
Turn on isdn debug on the pm 3 and see what it shows you.
:about 10 more tries both channels sync and I am finally running at 128k. No
:in my PM3 radlogs it shows nothing of my failed attempts. Tis like I never
:tried. This is also happening with people using regular 3Com Impact modems.
Again, turn on isdn debug and see if you see the 10 failed attempts.
:For my info in my PM3's:
:All PRI with switch of att-5ess
Did you check to see if your switch type on the pm 3 is set to 5ess still?
~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~
Jake Messinger, VP. ph:713-772-6690 Lucent Dealer
AMS, Inc. fx:713-774-3498 Medical Billing
8300 Bissonnet #400 jake@ams.com , ICQ# 4403734 Internet Services
Houston, Texas 77074 www.ams.com/~jake and Hardware
Adjunct Professor University of Houston, CBA jake@uh.edu
~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~
INVENTOR OF the _.,-*~''~*-,._ SQUIGGLES (c) 1978
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-modems' in the body of the message.