(PMOD) Rockwell/Conexant Disconnect Problems

Peter J. Ahimovic (pahimovic@lucent.com)
Mon, 22 Nov 1999 10:08:15 -0500

Rockwell/Conexant clients support the following at command:

at%e1

This will force the client to issue a retrain, when it would
normally issue a fast rate change.

at%e2 is the default which allows fast rate changes.

We have seen Rockwell/Conexant clients disconnect due
to a rate change failing. When this happens, the specs
say to issue a retrain. The problem is that a V.90 retrain
is about 20sec longer than a V.34 retrain. So in the V.90
case, something else in the client times out and hangs up.

Let us know if this helps.

- Peter
-