RE: PM-3 vs MAX 4002

Frank Heinzius (frimp@mms.de)
Fri, 13 Sep 1996 17:42:28 +0000

Hiya,

On 13 Sep 96 at 7:44, Kyle Townsend wrote:

> Sorry,
> I joined this RFE thing late. Are you saying that
> the Livingston DOESN'T support "hard-wired" BRI
> connections, or that the Ascend or RA6300 doesn't ?
>

Livingston DOESN'T
Ascend DOES
RA6300 DUNNO

> Also, is there anybody out there who understands
> frame relay over ISDN ? What's the advantage of
> this versus "hard-wired" ISDN ? Is it true that
> most TELCO's don't support this even if your
> hardware does ? Which of the three products under
> discussion supports this feature ?

I think the PM3 should do it, because with FR you use the same basic
Telco connection, e.g. E1 in Germany. It's just loading another
software in the Telco switches. The NT is the same here.

Frank

--
***** The expressed opinions are totally mine! *****
Frank M. Heinzius             MMS Communication GmbH
frimp@mms.de                  Eiffestrasse 598
http://www.mms.de             20537 Hamburg, Germany
Phone: +49 40 211105-0        Fax: +49 40 210 32 210
***** U.S.Robotics and Livingston Distributor  *****