Re: Stuck W1 port
John G. Thompson (jgt10@livingston.com)
Tue, 8 Oct 1996 16:32:14 -0700 (PDT)
On Tue, 8 Oct 1996, Helio Coelho Jr. wrote:
> At 00:04 09/10/96 +0200, you wrote:
> >
> >This looks like a telco problem but after replacement of the V.35 modem
> >and putting it on different wires it still continued:
> >
> >Tried Comos 3.1.4 and 3.3.2c2, same results. W1 functions for about a day
> >reading occasional frame and abort errors then all of a sudden it stays
> >on ESTABLISHED, idle time remains 0, but not a single bit can go thru;
> >the other side is a cisco saying "line protocol down". A reset W1 solves
> >it each time. Needless to say this is most annoying :-(
>
> I'm having just the same, in a PPP conection with a Cisco Router. The Cisco is
> running release beyond 10. After a reset the traffic just starts flowing again.
> I'm stuck...
> I'm running 3.3.2c1 in a Pm2er30.
>From the above it sounds like you have a connection running and then it
stops. What does the W1 port display (show w1) look like when traffic
isn't running? Are either the input or output counts increasing? Are
any of the error counts increasing? What does the Cisco report on the
link when the PM is 'stuck'?
If you need immediate assistance please call Livingston tech support at
800-458-9966.
JGT
--
John G. Thompson Livingston Enterprises Inc. Phone: (800) 458-9966
JOAT(MON) 6920-220 Koll Centre Pkwy. Fax: (510) 426-8951
support@livingston.com Pleasanton, CA 94566 http://www.livingston.com