Re: Stuck W1 port
Helio Coelho Jr. (helio@compuland.com.br)
Tue, 08 Oct 1996 21:50:51 -0300
>> >Tried Comos 3.1.4 and 3.3.2c2, same results. W1 functions for about a day
>> >reading occasional frame and abort errors then all of a sudden it stays
>> >on ESTABLISHED, idle time remains 0, but not a single bit can go thru;
>> >the other side is a cisco saying "line protocol down". A reset W1 solves
>> >it each time. Needless to say this is most annoying :-(
>>
>> I'm having just the same, in a PPP conection with a Cisco Router. The
Cisco is
>> running release beyond 10. After a reset the traffic just starts flowing
again.
>> I'm stuck...
>> I'm running 3.3.2c1 in a Pm2er30.
>
>>From the above it sounds like you have a connection running and then it
>stops. What does the W1 port display (show w1) look like when traffic
>isn't running? Are either the input or output counts increasing?
Both stop. In the console I got 'Session W1 disconnected destination ...'
> Are
>any of the error counts increasing?
I got a few CRC (3) and frame errors (5/2).
> What does the Cisco report on the
> link when the PM is 'stuck'?
I need to confirm, but I think it shows 'link down'.
>
>If you need immediate assistance please call Livingston tech support at
>800-458-9966.
Ok, Thanks!
Helio.
>
>JGT
>--
>John G. Thompson Livingston Enterprises Inc. Phone: (800) 458-9966
>JOAT(MON) 6920-220 Koll Centre Pkwy. Fax: (510) 426-8951
>support@livingston.com Pleasanton, CA 94566 http://www.livingston.com
>
>
>