>Is there a way to set different isdn-switch types for each PRI on
>a PM-3? We have a 2PRI-PM3. The Bell switch-tech tells us that
>one PRI is DMS-100 and the other is ATT-5ESS. When we set the box
>for NI-2, the DMS-100 based PRI seems to work fine, but the ATT-5ESS
>PRI returns busy signals after a few hours. A reboot of the box
>makes everything work for another few hours until it happens again.
>
The isdn-switch type is configured for the entire box. However, each of the two interfaces can be configured independently for line (PRI/T1/E1), framing, encoding, channelization, etc.
--Marty
****************************************************************
Marty Likier Livingston Worldwide Headquarters
Product Marketing Mgr. 4464 Willow Road
(800) 458-9966 Pleasanton, CA 94588 USA
(510) 737-2164 (510) 244-1903 (FAX)
marty@livingston.com Web:
<color><param>0000,0000,ffff</param>http://www.livingston.com
</color>****************************************************************