Re: E1 Interface + E&M wink start
Marty Likier (marty@livingston.com)
Mon, 12 May 1997 14:14:32 -0700
At 01:24 AM 5/8/97 -0400, Luis E. Mu#oz wrote:
>Dear Fellows:
>
>Anyone know if there is any ComOS release supporting E&M Wink
>Start on the E1 interfaces of a PM3? I was (mistakenly) informed
>by a Livingston rep. that the PM3 supported this signaling. Now
>I found out that this only applies to the T1 interfaces :(
>
>I'm in a desperate need for a solution to this issue. Any hints,
>references or anything will be welcomed :)
CE1/R2 signaling is not supported at the present time. However, we have
beta code running in Brazil on a Siemens switch.
--
Marty Likier
Product Marketing Mgr.