John
At 08:19 5/20/97, Douglas Warren wrote:
>Yesturday 5 of our BRI's went from everything being A-OK to NO-SERVICE,
>about 5 minutes later a NYNEX rep showed up to install a new 56k
>circuit, so I figured they fubarred something. Well, NYNEX just left us
>saying everything is okay on their end. And sure enough, when I plug
>the BRI into the BRI card on a PM2E-30 (20 serial 5 BRI) I still get
>no service, when I plug it into an OR-U, it comes up immediatly. The
>PM2 hasn't been rebooted, and here is the version information:
>Livingston PortMaster PM-2e ComOS 3.5b19
>System uptime is 25 days 2 hours 23 minutes
>show isdn reports:
>D Ports State Change Start Up Down Time Sess In Out Err
>-- ------- --------- ------ ----- ----- ----- ----- ------ ------- ------- ----
>10 S20/S21 Inactive 0 13412 75 21154 10589 29 273629 269715 17
>Wondering if anyone knows anything about something similiar, or if
>it's time to open a trouble ticket. I just noticed this one is
>running b19, while another PM2E here is running 3.5, wondering if a
>different ComOS would help any. I don't really wish to reboot to play
>with this as while the ISDN ports aren't in use, the Serial ports on
>it are. I'm open to any suggestions.
>
>---
>|Douglas ``Wildcat'' Warren |Email: dwarren@netusa.net| Jura gur tbireazrag
>|Network/Security Consultant|Phone: (516) 543-0234 | bhgynjf Pelcgbtencul,
>|President of SBCS a chapter| Fax: (516) 543-0274 | bayl pevzvanyf jvyy
>|of the ACM. | PGP: finger dwarren | unir cevinpl
--- John Harkin +1 415 472 1600 jh@nbn.com jh@best.net Director of North Bay Operations, Best Internet Communications Inc.