Re: PM3 connections

Robert Boyle (robert@garden.net)
Wed, 28 May 1997 10:18:48 -0400

At 06:59 AM 5/28/97 -0700, Jesse Martinez wrote:
>
> I have an evaluation unit and I'm having a decent amount of users
>complaining they can't get connected. They get a long tone after the
>handshaking begins. I'm trying to compile modem makes and model. So far I
>only have three. Telebit II 33.6, Motorola 56K and a Hayes 56k. I'm
>running 3.5c6 code on the PM3. Any help would be appreciated.

Both Livingston and Hayes are investigating the reported connect problem.
For the moment, have your customer enter
at+ms=11,0,2400,33600
This disables 56K mode and makes the modem work as a V.34, which connects
fine.

This is thanks to a number of people on this list. This particular quote is
from Marty Likier @ Livingston.

-Robert