Re: (PM) PRI and CT1 Question

Thomas C. Kinnen (tkinnen@livingston.com)
Tue, 09 Mar 1999 10:34:59 -0800

Ely Lucas wrote:
>
> Im looking at replacing my CT1s with PRI, but the sales rep from the telco
> I'm going through said I may have to get a PRI card for my PM3. It was my
> understanding that the PM3 can do both PRI and CT1 off the same interface,
> just with some line changes in ComOS. Can somebody set me straight on this?

The PM supports PRI or CT1 without any hardware changes. For PRI you will
need to set the line type to ISDN, change the encoding and framing if
needed, set the switch type, set the Directory numbers on the ports, and set
the SPIDS on the ports.

> Also, can the PM3 run a PRI on line0 and a CT1 on line1?

Yes it can.

-- 
Thomas C Kinnen - <tkinnen@ra.lucent.com> <tkinnen@sobhrach.com>
[RADIUS Test Engineer] - LUCENT Technologies RABU
"All of the opinions stated above are my own and not my employer's,
unless they were given to me by my employer"
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>