Re: (PM) RT328 Problems

Amir Nazary (anazary@staff.portal.ca)
Wed, 10 Mar 1999 15:22:46 -0800

I think something is telling me that BACP isn't going to work when the
ISDN call is initiated from the pm3 side.

Putting in an "&" between the telephone numbers didn't help either.

Does it work with p50's?

Thomas Kinnen wrote:
>
> Amir Nazary wrote:
>
> >
> > how do I put in the phone number string of the second B-channel for a
> > given location in the location table of the pm3? Should I even have to?
>
> You need to use the second number if the remote site does not roll over
> form the first number to the second on a busy. You can put it in the
> location using a & sign between the phone numbers. ex: 5551234&5554321
>
> --
> Thomas C Kinnen - <tkinnen@livingston.com> <tkinnen@sobhrach.com>
> [RADIUS Test Engineer] - LUCENT Technologies RABU
> "All of the opinions stated above are my own and not my employer's,
> unless they were given to me by my employer"
> -
> To unsubscribe, email 'majordomo@livingston.com' with
> 'unsubscribe portmaster-users' in the body of the message.
> Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>

-- 
Amir Nazary			#302 - 134 Abbott Street
System Administrator		Vancouver, BC CANADA V6B 2K4
Internet Portal Services	(604)257-9400
amir@portal.ca			www.portal.ca
--------------------------------------------------------
"85% of quoted statistics are fabricated"
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.