Please no HTML on the list.
> We've got 6 PM3's on 3 different hunt groups 1 on CT1
> the others on PRI after taking 23 calls it doesn't
> matter which hunt groups they come on all the rest of our customers
> start getting " all circuits are busy " from the phone switch
> telco clam's there is nothing wrong with there lines its our equipment
> so the big question is. Is it possible to configure the PM3's to cause
> this
If you set the rest of the ports for dial out only.
> or maybe something in radius.
> we did put 2 new PRI's in but there not working yet the new PM3' is on
> line
> the PRI's are down for this box
Sounds like the hunt group is not setup correctly. Now the big question,
did it ever work? And if it did what has changed?
-- Thomas C Kinnen - <tkinnen@ra.lucent.com> <tkinnen@sobhrach.com> [RADIUS Test Engineer] - LUCENT Technologies RABU "All of the opinions stated above are my own and not my employer's, unless they were given to me by my employer" - To unsubscribe, email 'majordomo@livingston.com' with 'unsubscribe portmaster-users' in the body of the message. Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>