FIXED Re: (PM) NO-SERVICE on E1 PRI

Mikel (mikel@sub.net.au)
Fri, 02 Apr 99 16:14:32 +1000

This was a Telco fault, they reset the PRI and it came good.

Sorry to fill the list.

In <199904020554.PAA11266@thrasher.sub.net.au>, on 04/02/99 at 03:45 PM,
Mikel <mikel@sub.net.au> said:

>I have a PM3 connected to a E1 EuroISDN (Australian Telstra Onramp) line
>running 3.8.2

>show line0 gives me:

> line0 - E1 Primary Rate ISDN
> Status: UP F1 Framing: CRC4 Encoding: HDB3 PCM: a-law

> Violations:
> Bipolar 0
> CRC4 0
> E-Bit 107
> FAS Bit 0

>The E-Bit errors are not increasing though (I have logged a call with the
>Telco none the less).

>show s0 gives me:

> Status: NO-SERVICE
> Modem-Status: DCD- CTS+ TELCO+

>show m0 gives me:

> Card Type: LU1675 Chipset
> State: Ready

>Now, a search on the WWW pages tells me that DCD- CTS+ TELCO+ means the
>line and switch type is fine but the SPID is not set. However, I didn't
>know you have to set a SPID on EuroISDN lines and further down the page
>indeed it says that SPID's only need to be set for US isdn.

>Help?

>Regards,

>Mikel

Regards,

Mikel

-- 
-----------------------------------------------------------
Mikel Lindsaar        |  "The dream is the foundation,
mikel@sub.net.au      |        of our society!" 
-----------------------------------------------------------
SubNet!                         http://www.sub.net.au/
-----------------------------------------------------------

- To unsubscribe, email 'majordomo@livingston.com' with 'unsubscribe portmaster-users' in the body of the message. Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>