Re: (PM) US Robotics V.90 and Portmaster 2

Robert Boyle (robert@tellurian.net)
Fri, 02 Apr 1999 23:47:10 -0500

At 01:34 AM 4/3/1999 -0300, you wrote:
>Hello,
>
> I had some problems with US Robotics Sportster v90 External and
>Portmaster 2.
> When I configure the modem type in portmaster, the connection between
>Client and Portmaster never is more than 33,600 bps. So I look for other
>init string, but no one work.
> Somebody configure these modem type with portmaster and have the right
>string ??? They need a special string to work fine ???

Carlos,

These will NEVER, EVER work at more than 33.6k. You must have one end of
the connection be digital and there cannot be more than one digital/analog
conversion in the entire signal path. You will need a PM3 (or an Ascend
Max, Cisco 5200/5300, USR HyperArc, USR Total Control, etc.) to offer 56k
v.90 service. I highly recommend the PM3!

-Robert

Tellurian Networks (Formerly Garden Networks)
Internet access for the earth since 1995
Access, Co-location, Development & Consulting
http://www.tellurian.net (888)TELLURIAN Ext.103
Finger robert@tellurian.net for PGP public key

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>