On 2 Sep 96 at 16:35, Peter Dellerman wrote:
> Hi,
>
> I run ComOS 3.3.2c1 on a PM2E with a 5BRI card. My TELCO (France
> Telecom) swears on a stack of phonebooks that I'am on EuroNumeris and
> thus my switch type should be "net3" (according to Livingston). The
> problem is that I have the NO SERVICE indication when I do "sh all". I
> have done the "set isdn-sw net3", "save all", "reset all" and re-booted
> with no effect.
>
> Does anyone know of instructions how to setup the 5BRI in general and
> in
> Europe (switch net3) in particular?
>
After setting the Switch type, you *have* to set the SPID and DN on
the BRI-ports. Just do
set s10 spid 0
set s10 dn 0
save s10
reset s10 (or reboot, if still NO-SERVICE)
It should work then. Please note that the 5BRI and the OR-ST are very
sensitive concerning cable length and bus termination on the S0-bus.
The cable to the NT should not be longer than 3 meters, if you want
more, use shielded cable types!
Another point: often the ISDN ports fail on the physical layer if
other ISDN devices are connected to the same S0 bus.
Frank