On Wed, 14 May 1997, Derek J. Balling wrote:

> Well, after hanging up from a sales rep @ Livingston who told me that the
> difference between the PM-3A and PM-3D was whether it was for North America
> or Europe (aggggggggh, salesdrones)... I decided I'd ask my questions here
> since the list appears WAY to be a way more knowledgeable place to ask.
>
> First, yes, I found the answer to that question above. :)

hehe for those who don't know the 3A is AC power supply 110/220V, the 3D
is DC power supply 48V... the T version is the US standard T1/CT1/PRI 24
channels the E version is for E1 Euro version 30 channels...

> The MDM-PM3-8 cards that Livingston has... Are they 56k modems? I may have
> missed something here in recent posts if this has already been discussed
> (sorry if I'm being redundant). The web site indicates that they're only
> v.34 but it strikes me as odd that a product "this cool" only does v34...

The Lucent DSPs are coming out in June hopefully, and I believe are rated
at least to 56Kbps. The current modem cards are V.34+ ( 33.6K down, 31.2K
up)

> Any information on this would be appreciated... If Livingston HASN'T got
> any 56k modem options, is there any suggestions the list-denizens may have?

Again 56K is scheduled, promised, destined for June...

--
Aloha,