Re: (PM) PM4 Crashed.

Matthew S. Crocker (matthew@crocker.com)
Mon, 22 Mar 1999 07:43:26 -0500 (EST)

On Sun, 21 Mar 1999, Paul Gregg wrote:

> I have a new Pm4 which has been up and running for over 40 days with
> comOS 4.0.3. PM4 has 2 power supplies both fed from different APC1000 UPSs.
>
> However, I popped into work this evening (Sunday) to begin a huge download
> and found that there was nobody dialled into the system... strange.
>
> Had PMVision open from Friday on the box - nothing showing there - PM
> vision wasn't responding. I also had a tenet session open on the box,
> it wasn;t responding either.
>
> Hooked up a console to the C0 port - hit return several times... nothing.
>
> I could ping the box, but other than that it was dead to the world.

This happens about one every other week to me. There is a known memory
leak in the PM-4 which Livingston has a closed beta release on.
My PM-4 is 100 miles away, I have 3 power supplies attached to APC
MasterSwitches so I can power cycle remotely.

-Matt

-- 
----------------------------------------------------------------------
Matthew S. Crocker 
Vice President / Internet Division         Email: matthew@crocker.com
Crocker Communications                     Phone: (413) 587-3350
PO BOX 710                                 Fax:   (413) 587-3352
Greenfield, MA 01302-0710                  http://www.crocker.com
----------------------------------------------------------------------

- To unsubscribe, email 'majordomo@livingston.com' with 'unsubscribe portmaster-users' in the body of the message. Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>