[Top] [Table Of Contents] [Prev] [Next] [Index]
7 out of 8 total pages
 

Cable Specifications   A


  This appendix provides pinout and length information for the following cables used on the PortMaster 4 and specifications for cables used on PortMaster 4 Ethernet interfaces.
 

       Modem Cable

  Table A-1 gives pinout specifications for an RS-232 modem cable with RJ-45 and DB-25 connectors.

  Table A-1 Modem Cable Pinouts

 
  PortMaster 4    Serial Port (C0, C1)        PC or Terminal    Serial Port 
  RJ-45    Name    Definition    Direction    DB-25    (DTE)    Signal 
 1  RTS  Request to Send  Output  5  CTS
 2  DTR  Data Terminal Ready  Output  81  DCD
 3  TXD  Transmit Data  Output  3  RXD
 4  GND  Signal Ground    NC2  
 5  GND  Signal Ground    7  GND
 6  RXD  Receive Data  Input  2  TXD
 7  DCD  Data Carrier Detect  Input  20  DTR
 8  CTS  Clear to Send  Input  4  RTS
 NC2    Data Set Ready    61  DSR
  Lucent recommends that the length of an RS-232 null-modem cable does not exceed
50 feet (15 meters).
 

       Console Cable

  Table A-2 gives pinout information for an RS-232 console (null modem) cable with RJ-45 and DB-25 connectors.

  Table A-2 Console Cable Pinouts

 
  PortMaster 4    Serial Port (C0, C1)        External Modem 
  RJ-45    Name    Definition    Direction    DB-25    (DCE) 
 1  RTS  Request to Send  Output  4
 2  DTR  Data Terminal Ready  Output  20
 3  TXD  Transmit Data  Output  2
 4  GND  Signal Ground    NC1
 5  GND  Signal Ground    7
 6  RXD  Receive Data  Input  3
 7  DCD  Data Carrier Detect  Input  8
 8  CTS  Clear to Send  Input  5

  1. Not connected.

  Lucent recommends that the length of an RS-232 straight-through console cable does not exceed 50 feet (15 meters).
 

       RJ-45 Cable

  Table A-3 shows the pinout specifications for a Category 5 twisted pair cable, as specified by the ANSI/EIA-568-A wiring standard, with an RJ-45 connector--also known as a RJ-48C connector.

  Table A-3 RJ-45 Cable Pinouts 

 
  PortMaster 4 Ethernet, T1, and E1 RJ-45 Ports 
  RJ-45    Signal    Definition    Direction to or from the PortMaster 4 
 1  RXD (Ring)  Receive Data  Input
 2  RXD (Tip)    
 4  TXD (Ring)  Transmit Data  Output
 5  TXD (Tip)    
  See "Ethernet Cable Specifications" on page A-3 for more information.
 

       Ethernet Cable Specifications

  Table A-4 provides cable specifications for the PortMaster 4 Ethernet interface.

  Table A-4 Ethernet Cable Specifications

 
  Ethernet     Type    Connector    Type    Cable Type    Transmission    Distance 
 RJ-45  RJ-45 for 10BaseT  Category 5 unshielded twisted pair1  A Category 5 distributed cable that meets the ANSI/EIA-568-A standard has a maximum length of 328 feet (100 meters), divided as follows:

  · 20 feet (6 meters) between the hub and the patch panel (if used)

  · 295 feet (90 meters) from the wiring closet to the wall outlet

  · 10 feet (3 meters) from the wall outlet to the desktop device

  · A maximum of four repeaters

 Ethernet cable must be grounded at both ends.
 RJ-45  RJ-45 for 100BaseT  Category 5 unshielded twisted pair1

  1.  For NEBS-compliant installations, Category 5 shielded  twisted pair cable must be used.


[Top] [Table Of Contents] [Prev] [Next] [Index]
7 out of 8 total pages